At Bay Area Air Conditioning, Inc., we put 48 years of experience to work for you. Our factory trained and certified technicians have seen firsthand the consequences of subpar materials, shoddy workmanship, and cheap products. Rather than tempt customers with the lowest prices, we earn your long-term satisfaction through top quality HVAC equipment and services. Our goal is to save you time and money with superior system reliability, longevity, and energy efficiency. Understanding the importance of sustainable solutions and long-term value, we uphold higher standards of business practices. Contact Bay Area Air Conditioning, Inc. at (888) 324-4033 for heating, cooling, air quality, and duct sealing services in Port Richey, FL, and we’ll serve your best interests.
Port Richey, FL: AC Repair & Air Conditioning Maintenance
Local Reviews
for Port Richey, FL
Happy Camper
Bill - Port Richey, FL 34668
Overall very satisfied. My only peeve is that a newbie brazed the line set and in my opinion was not good at it. The line was grossly over heated and might have cause internal O rings and pistons damage (time will tell). That job should have been left to someone more skilled. I know you would think I'm picky and how does one learn but by doing? True. Still, I believe that this type of skill should be practiced in the shop not in the field. In the end I am very satisfied with the price, equipment I chose, and the overall installation done by the crew. would recommend to others.
Thermostat
Leonard - Port Richey, FL 34668
Gray serviced
Michael - Port Richey, FL 34652
Great service
Service great, price not so great
David - Port Richey, FL 34668
Charged $87 dollars for looking for the problem I already briefed on. kept getting told that they would look at what needs to be done then and that would cost $87 even though I told the person on the phone and the tech on site what needed to be done. Over charge, I will use someone else in the future. The person doing the work was great.
Great Service!
Dorothy - Port Richey, FL 34668
Matt was the only one out of multiple companies to understand that even if the air was running, there could be a major issue with the system that was creating problems in my home. He recommended a two step process if necessary. My home is now comfortable and safe. He was efficient, easy to work with, and very customer oriented. I would recommend Matt Clinton and Bay Area Air Conditioning without reservation!
Owner
Michael - Port Richey, FL 34652
He was very informed and explained things to me
Nice tech!
John - Port Richey, FL 34668
Very knowledgeable and nice tech. Based on the estimates given, we are deciding on how to proceed.
Great Service, very patient and thorough
Huong - Port Richey, FL 34668
I always have good experience with Bay Area
Informative Helpful knowledgeable
Steven - Port Richey, FL 34668
After running the test this technician was very informative and knowledgeable
Install new system
Paula - Port Richey, FL 34668
Excellent and helpful with any question I had. Good installers and take pride in their work.
Awesome Service
Barry - Port Richey, FL 34652
Returned after being away for the summer and found that the AC wouldn't work. Jeff arrived quickly and made the repair in no time.
Great service
Edgar - Port Richey, FL 34668
Awesome Service
Lora - Port Richey, FL 34668
Very informative and spent time time on the tune up…very nice tech and professional
Prompt! Fair!
Sharon - Port Richey, FL 34668
I had Glen out today to fix my AC since it abruptly stopped working. He came out within a few hours and worked hard to get it to work again. Thank you for your honestly, fair price, and determination to leave me with a working AC without an immediate replacement!
Great Service
Cynthia - Port Richey, FL 34668
Glenn was very helpful. Great Service
Great service
John - Port Richey, FL 34668
Awesome
Jason - Port Richey, FL 34668
Honest and hard working. Thank you so very much.
Excellent service
Bruce - Port Richey, FL 34668
Inspected our 12 year old ac, and told us we still had "life" in it. Did not try to sell us anything.. Very pleased with the honest service which is rare in FL. So happy that we decided to get a service contract..
The attendant had to defrost the coil and then fill up the Freon price was reasonable and an excellent job
Chris - Port Richey, FL 34652
The attendant had to defrost the coil and then fill up the Freon price was reasonable and an excellent job. And showed up within half an hour after calling for service
Good service, pricing was fair
Michael - Port Richey, FL 34668
Very quick response
Excellent Service
Dorothy - Port Richey, FL 34668
I found Cliff to be clear, honest and low key. He showed me the reasons for his opinions and provided options.
Great
Alan - Port Richey, FL 34668
Extremely pleased with Jeff's work here today, explained everything clearly and gave some great tips to keep my system maintained. Highly recommend
Great service
Sheila - Port Richey, FL 34668
Excellent professional reliable service!
Service was efficient.
James - Port Richey, FL 34668
Leaking ac in ceiling
Dexter - Port Richey, FL 34668
This technician was great At communication. This has been the 5th time They have come out for similar shoes so let’s hope it’s fixed this time
Cleared out the lines and discussed a new AC
Michele - Port Richey, FL 34668
Pleased with the service.
Great experience!
T Phillips - Port Richey, FL 34668
I had a great experience with this company. I had to replace my a/c system and they thoroughly went through everything even after it was installed. All employees were courteous and very helpful. Would recommend this company to family and friends.
Took advantage of a situation did no work
Tesla - Port Richey, FL 34668
Great service very noligable and willing to teach me how to prevent my ac issue again
Jordan - Port Richey, FL 34668
Great service
Karl - Port Richey, FL 34668
AC went out at 4 o’clock in the afternoon they had me up and running by 545 that night

Paul@bayareacool.com
Completed maintenance on Goodman system. Checked refrigerant pressures, temperature splits, and static pressures. Vacuumed and flushed drain line. Cleaned indoor and outdoor coils. Washed and cleaned outdoor unit. Added 3 lbs of refrigerant. Noticed small oil stain under valve caps. Replaced old valve caps with new ones. System is running normally.

Paul@bayareacool.com
Completed maintenance on Carrier system. Checked refrigerant pressures, temperature splits, and static pressures. Vacuumed and flushed drain line. Cleaned indoor and outdoor coils. Washed outdoor unit and removed debris. System is running normally.

Paul@bayareacool.com
Completed maintenance. Checked refrigerant pressures, temperature splits, and static pressures. Vacuumed and flushed drain. Pulled and cleaned blower wheel and housing. Fixed loose flex in air handler. Washed and rinsed Condensor. Cleaned indoor and outdoor coils. Added 2 lbs of refrigerant to bring subcooling to 10. Unit is running at this time. Unit is 14 years old and was very dirty. Recommended to buy new system as well as duct work.

Matt C.
Found the humidity settings turned off. Adjusted the settings to allow dehumification. Corrected the humidity reading by 8 % and tested the cooling and dehumification.

Matt C.
Found that the air handler breaker was tripped. Checked all the connections and ensured they were secure. The heating element is pulling 41.7 amps. The customer told me before they replaced the breaker they had to push on the breaker to get it to connect to the electrical panel. The panel itself could be damaged at this point causing the breaker to over heat and turn off.

joevaught@bayareacool.com
10 year parts and 1 year labor warranty

Glen H.
Routine Tune Up All functions and operations were normal and within parameters Has no email Mail copies

Paul@bayareacool.com
Returned to take a picture of a main breaker that will need to be replaced.

Paul@bayareacool.com
Upon arrival customer stated that unit is not working. Found out that there is no 24v from transformer. Found no 240v coming into the breaker at the air handler as well as the breaker at the main panel. When I switched the breaker at the main panel off and back on, the 240v came back. Unit is running normally.

Glen H.
2/21 installed temporary motor & tested. Waiting on OEM motor

Jeff M.
Upon arrival the stat was blank. I checked float and it was dry. Homeowner said they had power surge early this morning. I reset breakers and system started. I set controller to cool 80 and was 75 in house. I showed homeowner which 2 breakers to reset if it ever happened again.

Jeff M.
Upon arrival the homeowner said it would not blow out real warm air. I removed the eco mode from controller to allow heat strip assist heat pump. I showed homeowner how to switch back to eco if he ever wants to. The trmp display on ecobee matched my probe temp and his external room thermometer.

Jeff M.
Upon arrival the homeowner said breaker would trip when heat strip came on. Homeowner replaced burnt breaker prior. I removed heat strip and inspected. I could jot see anything wrong. I reinstalled strip and it worked fine. It was only pulling 34 amps and not tripping breaker. I did jot find any wrong at this time. Another company said it was pulling 70 amps.

Jeff M.
Upon arrival I installed defrost board and installed a UV light kit. It is cooling at this time. UV light is working.

Matt C.
Completed the maintenance inspection.

Jeff M.
Homeowner had me reschedule till after the 1st of the month.

Glen H.
Installed new heater assembly with appropriate wire harness & tested(34amp) Blower motor was suspect on prior call, confirmed both operating power and control signal at motor, motor wont respond Need motor 1/3hp Today's charges (160.00) to be transferred to next invoice for motor replacement

Matt C.
Repaired the refrigerant leak, pressure tested with Nitrogen, pulled a vacuum down to 450 microns and adjusted the Subcooling to 10 degrees. Two year labor warranty on today's refrigerant repair.

Jeff M.
Upon arrival the heat was luke warm. The system was in auxiliary heat and is only a 5 kw heater. I checked amps to heat strip. Then I checked in heat mode. I checked pressures and and were good. I explained that system should be in heat mode not emergency heat. I explained how air will be luke warm during defrost cycle only because of a 5 kw heatstrip. I explained all functions of controller and house was heating well when heat pump was working.

Matt C.
Installed the infinity controller and rewired the system. Programmed the thermostat and explained how to operate the stat. Also noticed a small leak at the air handler. We will be returning to repair that issue at another date.

Bill H.
Could not get ahold of customer tried twice. Voice mail was full

wesley@bayareacool.com
Found that float switch is stuck open could not get to work replaced, system is now operating.

Paul@bayareacool.com
Upon arrival, customer stated that the unit is not running. Inspected and found that there was no 24v out of transformer. Installed different transformer and still found no 24v. Inspected breaker and found only 1 leg sending power. 60 Amp 2 Pole Cutler-Hammer Breaker in air handler must be replaced.

Jeff M.
Upon arrival the condenser was stuck in the defrost mode. I found defrost board burnt. I got system out of defrost mode and is heating. I submitted quotefor new board and sensor. Homeowner asked about a quote for UV Bulb kit. I quoted kit. I instructed Homeowner it might stick again when frost starts building on coil and needs to defrost. Homeowner is waiting on defrost board quote. Goodman system.

Matt C.
Found a blown fuse due to a low voltage short at the condenser. Repaired the wire and replaced the fuse. The system is up and heating.

Matt C.
Replaced the high voltage wiring, breaker, and heater for the air handler. Upgrade from a 5 kw to a 10 kw heater. David to bill customer

Jeff M.
Upon arrival the house was not warming up. I turned heat on to see if heat strip was working. It was working. The problem is that it is a straight cool system and only has heat strip for heating. They only have a 5kw strip. They need a 10kw. The reasoning for the 5kw is that there is only #10 romex going to airhandler. A new branch circuit would need to be ran to the breaker box across the room. The panel is a 150amp service. A new heat strip,breaker and #6 wire need ran to correct problem if electrical codes can be met. Nothing I can do at this time to get more heat.

Jeff W.
No heat strip. Customer states Em heat previously disconnected but thermostat has been replaced since. I reconnected wiring and test operation. Heat strip comes on when call and off for cooling. Added 2 lbs R410A. OD fan motor not coming on. Quote new equipment.

Jeff W.
Called, no answer. Sent email for estimate of drain line only replaced.

Jeff M.
Canceled call tonight. It is too late but wants service tomorrow morning
Air Conditioning Service & Installation Throughout Port Richey, FL
Bay Area Air Conditioning, Inc. handles the seasonal maintenance of all makes, models, and styles of HVAC equipment, completing Higher Performance Tune Up and Cleaning, to combat wear and tear, malfunctions, higher running costs and premature failure. For any problems you may encounter, count on us for rapid response, free second opinions, and repairs that hold up to time, weather, and demand. We customize recommendations and sizing of new installation to suit your specific requirements, protect your investment with our ten year parts and labor warranty, and always verify the performance data. Bay Area Air Conditioning, Inc. delivers exceptional results to our residential and commercial customers in Port Richey, FL.
AC Service ∴ Air Conditioning Maintenance ∴ Port Richey, FL
AC Installation ∴ Air Conditioning Maintenance ∴ Port Richey, FL